Spectroradiometer 250 - 900 nm and 360 - 900 nm

ILT560 from International Light Technologies

The ILT560 comes with a SMA905 receptor as standard, allowing it to be used with all of the ILT950 spectroradiometer accessories including the R4 Right angle adapter, mini and standard diffusers, fiber optics, 2, 5 and 10 inch integrating spheres.

Standard and optional accessories can be combined to allow measurement of total flux, irradiance, radiance, colorimetry, luminance, illuminance and more.

Features
NIST-traceable, ISO17025 accredited calibration
UV-VIS-NIR-Range
Resolution: 1.2 nm with 50 micron slit
Focal length: 75 mm
Symmetrical Czerny-Turner

SpectriLight III – ILT560 series control & analysis software

SpectriLight™ III is a LabVIEW based software package for Windows that allows you to acquire spectral and color data.

The new version 3.5.3 of SpectriLight™ III has additional calculations for metamerism, and 2 and 20 degree observer and TM30-15. The new overlay feature allows the user to compare the base reading to current readings. Wavelength range, integration time, scan average and other controls can be easily set through pop up windows, menus and tool bars.

Absolute irradiance and chromaticity are calculated instantly.

SpectriLight™ III is LabVIEW based software and can be easily customized for specific OEM applications. For API applications, Multiple DLL’s are available.

Specifications

  • Automated time line measurements
  • Access multiple calibration files
  • Auto-integration simplifies user interactions
  • Scan average: 1 to 999 for reduced noise
  • Peak find
  • Enhanced scaling and zoom features including movable vertical cursors
  • Export to ASCII text or directly into Excel. Save screens/scans in multiple formats including
    .bmp, .jpg, and .png
  • Powerful import data wizard can even import data from other spectrometers

SpectriLight™ III version 3.53. new features

  • Overlay: allows comparison to baseline reading
  • PAR: plant growth calculations
  • New color calculation includes 2 and 10 degree observer, and metamarism

Optional input optics

ILT-R2 Radiance optic
Specialized fiber optic produces an average field of view of 2 degrees
for radiance/luminance measurement of extended sources. Requires ILTVS950R calibration.
ILT-RAA4 Right angle cosine adapter
with approx. 6.9 mm diameter aperture, permits measurement of light sources 90º to the standard fiber. Sold with weighted screw-on handle for more stable detector placement when needed. Excellent cosine response, increases signal transmitted to CCD spectrometer, excellent for lower light, low profile, and small diameter light pattern measurements. Calibration required (sold separately).
ILT-INS50 2-inch Integrating sphere
with 2 ports; SMA905 and 5 mm port with lambertian response. For testing mounted and unmounted LEDs, fiber optics and miniature lamps. Provides readout of total flux in watts and lumens, irradiance in W/cm2, illuminance in lux, color purity, spectral distribution and color temperature with ILT560 (requires ILT-VS950P calibration). Alternative: ILT-INS125 5-Inch Integrating sphere and ILT-INS250N 10-inch Integrating sphere.
ILT-FFOSMA2UV1000
2 meter long, 1000 micron, armored fiber optic light guide. Transmits light from 250 -1050 nm. Strong armored cable adds additional protection against breakage often required for longer fiber lengths.

Real-time analysis

  • Irradiance: Total, Visible, UVA, UVB, UVC, PAR and photopic data
  • Selectable bandwidth for irradiance, power and radiance (requires additional hardware and
    calibration options)
  • Chromaticity analysis: x, y, u, v coordinates and display in CIE color spaces
  • Dominant and complementary wavelength and color purity
  • General Color Rendering Index (CRI) and 15 special color rendering indices
  • Correlated Color Temperature (CCT) and DUV
  ILT560A Broadband ILT560 UVA-NIR ILT560-I
Spectral Range 350 - 900 nm standard* 360 - 900 nm 600 - 1000 nm
Stray Light <0.1% @600, 435 nm <0.2% <0.2%
AD Converter 16 bit, 2MHz 16 bit, 2MHz 14 bit, 2 MHz
Signal/Noise 400:1 220:1 200:1
Integration Time 0.5 ms - 10 sec 1.05 ms - 10 minutes 1.05 ms - 10 minutes
Interface USB 2.0 USB 2.0 (480 Mbps) USB 2.0 (480 Mbps)
Power Supply USB power USB power USB power
Dimensions (mm) 91 x 60 x 34.5 95 x 68 x 20 95 x 68 x 20
Temperature Range 5 - 35 degrees C 0 - 55 degrees C 0 - 55 degrees C
CCD 2048 2048 2048
Resolution 1.5 nm 1.2 nm <1 nm
Slit 25 micron 50 micron 25 micron
Software Win XP, Win7, Win 8, Win 10 Win XP, Win7, Win 8, Win 10 Win XP, Win 7, Win 8, Win 10

* ILT560A Broadband 250-900 nm requires RAA4 and dual source calibration upgrade

LED test & measurement
Plant Growth/PAR/Plant Photobiology
Characterization of Solar Simulation
Characterization of UV Curing Systems
Photostability Testing
Accelerated Weathering
Radiometery and Photometry Measurements
LED Illumination and Color Analysis
Absorbance/Transmittance of Fibre optics
Reflectance
Fluorescence

Contacts